Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13671478

- Product Categories
- Friendly Links
Information Name: | Automatic fire pump inspection TH-X-XF Series cabinets fire inspection |
Published: | 2015-03-18 |
Validity: | 30 |
Specifications: | TH-X-XF |
Quantity: | 1111.00 |
Price Description: | |
Detailed Product Description: | Model specifications are as follows: TH-X-XF-22 / 4T, TH-X-XF-30 / 4T, TH-X-XF-37 / 4T, TH-X-XF-45 / 4T, TH-X-XF- 45 / 6T, TH-X-XF-50 / 4T, TH-X-XF-50 / 6T, TH-X-XF-55 / 4T, TH-X-XF-55 / 6T, TH-X-XF- 70 / 4T, TH-X-XF-70 / 6T, TH-X-XF-75 / 4T, TH-X-XF-75 / 6T, TH-X-XF-90 / 4T, TH-X-XF- 90 / 6T, TH-X-XF-90 / 8T, TH-X-XF-93 / 6T, TH-X-XF-110 / 4T, TH-X-XF-110 / 6T, TH-X-XF- 110 / 8T, TH-X-XF-132 / 6T, TH-X-XF-160 / 6T, TH-X-XF-187 / 6T, TH-X-XF-200 / 6T, TH-X-XF- 220 / 6T, TH-X-XF-250 / 6T, TH-X-XF-280 / 8T, TH-X-XF-315 / 8T, TH-X-XF-400 / 8T, TH-X-XF- 500 / 8T, TH-X-XF-630 / 8T, TH-X-XF-800 / 8T TH-MR and other digital intelligent fire inspection control module TH-EIZ digital intelligent inspection interface TH-X-XF inverter controller TH-X-XF-37/4/6/8 TH-X-XF-45/4/6/8 TH-X-XF-55/4/6/8 TH-X-XF-90/4/6 / 8 TH-X-XF-110/4/6/8 TH-X-XF-132/4/6/8 TH-X-XF-160/4/6/8 one, consisting of one pair of power protection equipment investment automatic inspection of the control cabinet 2 3 fire pump control cabinet control cabinet two main circuit, a device the size of a standard size 800 * 600 * 22 002 depending on the design, site conditions can be customized to any size TH-X-XF fire pump control equipment is automatic inspection I Company in accordance with the requirements of public security GA30.2-2002 standard developed specifically for enterprises, intelligent fire protection system fire pump control routine patrol inspection equipment; products using programmable logic controller, inverter and human-machine interface control technology, were set on fire pump cycle, given time, will speed 巡迴 detected by automatic inspection, the fire pump in a reliable long-term operation. Three, TH-X-XF inspection cabinet features: 1, inspection function: TH-X-XF inspection cabinet automatically according to the set of cycle-by-fire pump low-speed inspection, usually when a single pump inspection speed of 300 rev / min for 10 minutes running time of inspection; (time period can be set on demand) and can automatically switch hands patrol through the switch. 2, automatically exit inspection functions into the Fire: TH-X-XF patrol signal fire cabinet met in the inspection process automatically exit polling, entered the fire running. 3, alarm and protection functions: TH-X-XF patrol cabinet also has short-circuit, over-current, electrical power failure alarm and fault protection, found fault audible alarm signal in the inspection process, the alarm system failure memory function, record the time of failure and the failure of the content. 4, remote monitoring and control functions: TH-X-XF inspection cabinet according to the user's needs, configure remote monitoring and control module, and the fire control center via bus communication, the purpose of the fire control center monitoring system operation. 5, mobile phone alarm function: according to the user's needs TH-X-XF inspection cabinet also configure your phone alarm module, when a fault occurs, the fault message is sent via mobile phone to the user's mobile phone to alert the user in time. 6, water feature with pressure test: TH-X-XF inspection counters can also be configured according to the fire lines, with pressure on the pipeline system to test the water, the use of pressurized water test inspection of equipment, piping should be proof overpressure measures provided relief loop inspection equipment, set the loop should be safe and reliable. The device has a main circuit inspection and fire inspection equipment without pressure of two parts, to be completed by the low-speed automatic inspection of the main circuit and pumps. When the system has no firefighting command and fire control equipment for each system to automatically switch to the state, TH-MR intelligent controller output patrol inspection by one of the main loop command inspection, patrol the return signal is taken from the various electrical components of the primary secondary contacts. The feedback signal is not greater than the time allowed 2S. After the completion of the main circuit inspection, TH-MR Patrol controllers will happen next instruction to patrol without pressure inspection device TH-X-XF, the device after receiving the inspection instructions will be followed for the fire pump at low speed without pressure inspection. When the patrol motor speed is low, the system does not generate pressure. The entire inspection process, such as the device receives the fire command TH-MR intelligent controller will issue a Stop Patrol Patrol command immediately, instant start fire pump complete firefighting tasks. Abnormal movements such as the inspection process, the controller will record the number of faulty and fault slip category, concurrent sound and light alarm. While storing the digital intelligent interface TH-EIZ inspection and record failure information for inspection, digital intelligent inspection interface TH-EIZ for Chinese finished display, easy to operate. Simultaneously upload failure (can be transmitted to the fire in the control room or floor control duty room) notify maintenance personnel on duty to ensure foolproof fire-fighting equipment. When non-fire state, the use of TH-MR digital controllers intelligent fire patrol fire automatic inspection control equipment, fire pumps can do automatic inspection operation. Automatic inspection cycle for a few hours to several hundred hours, optionally, the clock cycle starts automatically with manual inspection procedures and inspection functions. When the inspection, the main circuit TH-MR digital intelligent fire inspection controller will fire control cabinet for testing to confirm normal to low speed by one driven fire pump is running at low speed so that, when the driving power is very small, about hundredth pump motor power rating so, so significant energy saving. Due to the low speed, so it will not pressurized water supply pipe network. If you run the command while receiving the fire inspection, the local control unit will immediately interrupt polling operation, the control device to power-frequency-driven fire pump into the fire command is run. Only in the next period and no inspection when the fire occurred, began running a new inspection process. When the inspection, if the pump fails fault alarm information will be given. When an input overvoltage, undervoltage, phase, output over-current, TH-MR controller will issue a warning message to the fire center a short circuit. This result ensures automatic inspection of the fire pump will not rust, rust phenomenon, the fire water supply equipment "idea that day, military forces while" a reality. The device also has a standby pump automatically swap, when the main pump failure, the standby pump automatically input; standby power automatic mutual investment, when the main power supply failure, the standby power is automatically put into other functions; TH-MR digital intelligent control fire inspection automatic fire control equipment inspection would be composed of all of the above features provide remote data, image monitoring, fault alarm, message printing and other functions. Digital intelligent fire inspection cabinet TH-MR TH-EIZ TH-X-XF The company also supplies these products to similar products: JH-XF digital intelligent inspection cabinet, UE-XF digital intelligent inspection cabinet, TW-FAW digital intelligence Patrol cabinet |
Admin>>>
You are the 15117 visitor
Copyright © GuangDong ICP No. 10089450, Xian Fang Electric Co., a All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 15117 visitor
Copyright © GuangDong ICP No. 10089450, Xian Fang Electric Co., a All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility