Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13671478

- Product Categories
- Friendly Links
Information Name: | TH-X-XF fire inspection cabinet th-24mr |
Published: | 2015-04-01 |
Validity: | 30 |
Specifications: | |
Quantity: | 1.00 |
Price Description: | |
Detailed Product Description: | TH-X-XF-75/4 digital intelligent fire inspection counter (hereinafter referred to as the TH-X-XF digital automatic fire inspection equipment) is the company in accordance with the standards development and production of intelligent fire protection system fire pump control equipment; fire-fighting equipment available By TH-X-XF-75/4 digital automatic inspection, the fire pump long-term reliable operation. 1, GB50045-95 "fire protection design of tall buildings," explained the provisions of 7.5.4 clearly stated: "fire pump should regularly run checks to verify the electronic control system and pump unit itself is normal, how quickly should start testing. Determination of the pump flow and pressure test the water when the pool from the fire, can return to the pool. " 2, GB50016-2006 "building design for fire protection" provisions of 8.6.5 explain clearly stated: "To facilitate the testing and inspection of fire pumps, pressure gauges should be installed and the nominal diameter of 65mm at its outlet drain valve should be checked regularly. Whether the fire pump can operate normally, and test fire pump flow and pressure. " 3, 9.0.4,9.0.11 provisions GB50261-2005 "automatic sprinkler system construction and acceptance" of clearly defined: 5. The provisions pump inspection function switch: The equipment should have the main fire pump or regulator generates the main pump When electrical failure or inability to achieve the desired capacity, the standby pump should be able to automatically and manually switch inputs. 6. The ability of anti-system disturbances: Method of test equipment according to the provisions of this standard 6.4.7, should be able to work properly, with no pressure oscillations or shutdown protection phenomenon. 7. Remote Control: Equipment should display output terminals and remote fire pumps work status and fault conditions to start the fire pump control input terminal. 8. Protection: The equipment should have for short circuit, over current, electrical power and other fault alarm and automatic protection. Recoverable fault should be able to automatically or manually eliminated, resume normal operation. 1. The equipment should have automatic and manual inspection functions, the automatic inspection period should be set on demand. 2. Fire-by-fire pump control station up and running, each pump running time of less than 2min. 3. In case of fire fighting equipment should be able to ensure that the signal in the inspection process automatically exit polling, entered the fire running. 4. fault found during inspection should sound and light alarm. Device with fault memory function, the time of failure and failure type shall be recorded, should not less than five fault information, which should be clear and understandable display. 9. man-machine dialogue: a human-computer dialogue-enabled devices, dialogue interface should be finished, everything clearly recognizable icons for easy operation. Water supply capacity of a single pump flow characteristics: Each pump is working according to the test method specified in 6.7.1, the maximum deviation of the measured value and the nominal value of not more than 10%. 2, equipment, water supply capacity of 300, water supply capacity of the equipment should not be lower than the set of parameters. 4, equipment selection should match pump water supply equipment capabilities. Feedwater pumps in parallel flow pressure loss at the time of the fire service must not be greater than 5% at this pressure and the flow rate of each single pump. Provides a continuous operation, the equipment in the state should be able to run continuously Fire 6h, the components may not affect the normal operation of the fault. 2, the document clearly states: Fire inspection event occurs, the device immediately stop the patrol instantly start the fire pump, the main pump failure standby pump automatically put into operation, concurrent sound and light alarm. 3. Speaking Chinese patrol interface, the system disturbance rejection capability and the ability to test the water supply and fire-fighting equipment and other functions to ensure instant start the fire command after encountering fire pumps, fire fighting tasks to complete. Relevant standards Specifications Model: TH-X-XF-22/4, TH-X-XF-30/4, TH-X-XF-37/4, TH-X-XF-45/4, TH-X- XF-45/6, TH-X-XF-50/4, TH-X-XF-50/6, TH-X-XF-55/4, TH-X-XF-55/6, TH-X- XF-55/8, TH-X-XF-70/4, TH-X-XF-70/6, TH-X-XF-75/4, TH-X-XF-75/6, TH-X- XF-90/4, TH-X-XF-90/6, TH-X-XF-90/8, TH-X-XF-93/6, TH-X-XF-110/4, TH-X- XF-110/6, TH-X-XF-110/8, TH-X-XF-132/6, TH-X-XF-160/6, TH-X-XF-187/6, TH-X- XF-200/6, TH-X-XF-220/6, TH-X-XF-250/6, TH-X-XF-280/8, TH-X-XF-315/8, TH-X- XF-400/8, TH-X-XF-500/8, TH-X-XF-630/8, TH-X-XF-800/8 etc. TH-X-XF series intelligent digital control. TH-X-XF Series digital intelligent fire an automatic inspection equipment, the need for intelligent automatic fire pump inspection of the company pursuant to the performance requirements and test methods for the Ministry of Public Security Fire Safety industry standard GA30.2 fixed fire water supply equipment for the fire pumps to prevent corrosion, moisture, water pump action is not normal fault, really do "idea that day, military forces while" objective |
Admin>>>
You are the 15117 visitor
Copyright © GuangDong ICP No. 10089450, Xian Fang Electric Co., a All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 15117 visitor
Copyright © GuangDong ICP No. 10089450, Xian Fang Electric Co., a All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility