Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13671478

- Product Categories
- Friendly Links
- home > Supply > Digital intelligent fire inspection cabinet TH-X-XF, TH-MR, TH-EIZ, TH-Z4MR series, Lanzhou, Shenyang factory outlets, offers ongoing ......
Digital intelligent fire inspection cabinet TH-X-XF, TH-MR, TH-EIZ, TH-Z4MR series, Lanzhou, Shenyang factory outlets, offers ongoing ......
Information Name: | Digital intelligent fire inspection cabinet TH-X-XF, TH-MR, TH-EIZ, TH-Z4MR series, Lanzhou, Shenyang factory outlets, offers ongoing ...... |
Published: | 2015-04-07 |
Validity: | 30 |
Specifications: | TH-X-XF, TH-MR, TH-EIZ, TH-Z4MR |
Quantity: | 1.00 |
Price Description: | |
Detailed Product Description: | A detailed description of TH-X-XF digital intelligent fire inspection equipment manufacturers: TH-X-XF digital intelligent fire inspection equipment manufacturers TH-X-XF fire inspection control cabinet Overview TH-X-XF is a fire inspection control cabinet According to the National Fire Protection Standard GBJ16-87 "building design for fire protection" and GB50045-95 "design of tall buildings waterproof standard" design and production, dedicated to the high and low industrial, civil fire protection, sprinkler, water curtain, rain, fire tube Net regulator, booster pumps, etc. to control, users can meet a variety of different control the fire pump. Fire inspection control cabinet Features ◆ Reliability: Based on mature industrial control software and hardware product architecture level. Acceptable multiple signal fire, convenient and reliable network control center and fire, and fully meet the requirements of practical situations (a button to manually start .2, .3 each hydrant switch to start, start .4 pressure, start the fire center. (2,5, emergency control button to start.) ◆ TH-X-XF fire inspection cabinet can keep the fire pipe network maintenance and pressure, to ensure that the initial fire extinguishing the fire with water, can reduce the loss and damage caused by fire; ◆ TH- X-XF fire inspection control cabinet features a pump on, the pump stops, pump failure, such as passive contact feedback fire center; ◆ TH-X-XF fire inspection intelligent cabinet has the following characteristics: 1, when the inspection, such as the case Fire signal automatically exit into the fire running, to ensure the normal operation of the fire when the fire pump; 2, when the water pump fails, the standby pump automatically input and alarm, fault repair work automatically, and automatically switch to the standby pump ◆ energy:. by the time the fire broke out, "fire hydrant control" the first time put into the fire pump to run in the "pressure control" run the pump, the system automatically according to the signal pressure to work to avoid the fire occurred when all pumps start all put pressure on the fire pipe network too large and energy waste ◆ scalability: According to the user's needs increase or decrease any software module; ◆ comprehensive alarm system alarm level is too low, the water pump and spare pump failure alarm from the cast (with fault raw, light and alarm functions with fire duty interactive user interface); ◆ has a pump motor overcurrent, overvoltage, undervoltage, voltage, phase, circuit protection function; ◆ inspection functions: manual / automatic inspection function (inspection cycle, inspection time can be set), it is to monitor and data acquisition (SCADA) systems based on the use of industrial automation and control technology to detect, automated monitoring and control can be realized without pressure pump is running in a state inspection and process operations by touch-screen display users can stop by inspection of the fire pump caused by corrosion, improve the reliability of the fire protection system;. and effectively reduce the intensity of the daily work of maintenance personnel to improve system reliability and system maintenance cost savings. Fire inspection counters: "NOTE" ◆ increase dual power automatic switching function, in order to protect the system of uninterrupted power supply, reduce property damage; ◆ powerful pumps can drive or soft starter to achieve a smooth start to alleviate the pump start When the impact of the grid pipe network; ◆ according to user needs to design a variety of fire control methods; technical parameters ◆ Environmental conditions: non-explosive dust and corrosive gases ◆ Working temperature: 0 ~ 40 degrees Celsius ◆ Operating Humidity: 80% ◆ No condensate supply conditions: 380V / 220V.3 phase .50Hz voltage offset 10% fire inspection control cabinet manufacturing standards in strict compliance with the International Electrotechnical Commission IEC standards and China's national standard GB ◆ GB 50052-95 supply and distribution. system design specifications ◆ GB 50054-95 low voltage power distribution design specifications ◆ GB 50055-93 common electrical equipment distribution design specifications ◆ GA-30.2-2004 national public safety standard fire inspection of the control cabinet Come buy good products. Intelligent fire inspection equipment: Features: 1. Pump intelligent automatic inspection, to prevent rust pumps, electrical protection equipment normally the main loop detection 2. 3. pools, water tanks, water collection pit display, remote control 4. pump automatic inspection by one motor tidal flooding, low water pressure during operation is only 3-10 meters, pipeline inspection avoid overpressure problems 5. Can be set to manual inspection mode, there are regular inspection prompted to set 6 . received a signal fire, and instantly switch to exit polling state normal startup mode 7. The device status, the water level in the control room remote display 8. 9. Record inspection run record set aside to save nine 10. RS485 communication interface, for connecting the building to be completed by the automatic system and fire control room to the fire pump to run into the city fire remote monitoring system 11, recording information print function 12. SMS prompts low-frequency low-speed automatic inspection has exclusive patented technology, when fire inspection wrong pressurized water supply network, can be arbitrarily set automatic inspection cycle, a few hours to several hundred hours fire pump inspection, while energy consumption is only when the fire patrol around 2% of rated power. TH-X-XF digital intelligent control cabinet fire inspection operation mode when running in the fire, with anti-overpressure device, when the fire occurred, fire automatic inspection control cabinet immediately terminate inspection, in order to start the pump power frequency, if the main When the pump fails, the standby pump automatically open. TH-X-XF digital intelligent fire inspection control cabinet with the fire center networking, but also realize remote data transmission fire inspection, fire inspection remote control can also be achieved fire inspection of hot standby dual control system (optional), or remote computer system status display real-time images. TH-X-XF digital intelligent fire patrol use low-voltage control cabinet and its unique fire inspection techniques are TH-X-XF is indeed a unique product. The digital intelligent fire inspection of the control cabinet to the greatest degree of protection using fire-fighting equipment availability, and thus the greatest degree of protection of life and property of the people. |
Admin>>>
You are the 15117 visitor
Copyright © GuangDong ICP No. 10089450, Xian Fang Electric Co., a All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 15117 visitor
Copyright © GuangDong ICP No. 10089450, Xian Fang Electric Co., a All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility